75 kva transformer weight

The following is the **weight reference** for a **75 kVA transformer**, covering **dry type and oil-cooled type**, as well as 

**common brand models in the United States**, and attached with **model selection suggestions**:

 I. Core Weight Data (Mainstream Models in the US Market)

TypeTypical Brands and ModelsWeight (in pounds)Dimensions (in inches)Installation Environment
Three-phase Dry TypeSquare D QO75T3H544 pounds30×20×37 (Width×Depth×Height)Indoor (NEMA 1)
Three-phase Oil-cooled TypeEaton 4468 (150 kVA) 700 pounds49×37×46Outdoor (NEMA 3R) 
Three-phase Oil-cooled TypeGeneral Electric GE 9T213BC3Approximately 600 pounds36×24×40 (Estimated)Outdoor/Indoor
Single-phase Dry TypeHammond 167H (30 kVA)180 pounds18×12×24Indoor

II. Key Explanations

1. **Dry Type vs Oil-cooled Type**

   - **Dry-type Transformer**: Light in weight (approximately 500~600 pounds for 75 kVA), suitable for indoor installation 

due to the absence of cooling oil.

   - **Oil-cooled Transformer**: The weight of a 75 kVA oil-cooled transformer is **usually 20%~30% heavier than that of a 

dry type** (estimated to be approximately 600~700 pounds), including transformer oil and a heat dissipation structure.

2. **Brand Differences**

   - Square D QO75T3H (544 pounds): **The most common model in the United States**, UL certified, with an installation bracket attached.

   - General Electric GE 9T213BC3: **75 kVA oil-cooled type** (Unofficial data), which is 14% lighter in weight than the Eaton 150 kVA model.

III. Model Selection and Installation Precautions

1. **Transportation and Hoisting**

   - A 75 kVA dry-type transformer requires **2 to 3 people for handling**, or a forklift can be used (with a pallet interface at the bottom).

   - An oil-cooled transformer requires **a forklift + slings**, and pay attention to the balance of the center of gravity (there are 

lifting rings at the bottom).

2. **Load-bearing Capacity of the Installation Base**

   - Indoor: The cement floor needs to bear a load of **≥600 pounds per square foot** (for dry type).

   - Outdoor: An oil-cooled transformer requires a **concrete foundation** (with a thickness ≥6 inches and an area ≥4×3 feet).

 IV. Quick Inquiry Suggestions

1. **Confirm the Model**

   - If it is **Square D QO75T3H**, directly refer to **544 pounds** (which can be found in the official manual).

   - For other models (such as Eaton 75 kVA), contact the supplier to obtain the **Spec Sheet**.

2. **Second-hand Transformers**

   - When searching for models on eBay or Surplus Record, the **weight is often indicated in the "Shipping Details"**.

**Conclusion**: The weight of a 75 kVA three-phase dry-type transformer is **approximately 544 pounds** (such as Square D),

 and that of an oil-cooled type is **approximately 600~700 pounds**, subject to the specific model.